Richway Industries
Mix Design App
Units
Water to cement ratio (w/c)
0.60
0.2 0.8
Portland cement
—
lbs / yd³
Water
—
lbs / yd³
Slurry density
—
lbs / ft³
Dry cellular densityRange: 20 – 90 lbs/ft³
Total cellular volumeDefault: 1 yd³
Wet cellular density
—
lbs / ft³
Base slurry required
—
yd³
Total water required
—
gal
Foam concentrate required
—
gal
ℹ Water required and foam concentrate are calculated using foam density of 2.5 lbs/ft³ and water:concentrate ratio of 40:1.
Purchase CMX Foam Concentrate
Advanced settings
Fly ash replacementSG: 2.60 | Default: 0%
%
Pozzolan #2 replacementSG: 2.33 | Default: 0%
%
Aggregate/cementitious ratioSG: 2.65 | Default: 0%
%
Sand/cementitious ratioSG: 2.65 | Default: 0%
%
Foam concentrate costPer gallon
$
Base slurry costPer yard
$
Cost of foam needed
—
USD
Cellular slurry cost per yard
—
USD / yd³
CT-30D
Slurry pump: 100–300 RPM
Selected
CT-100D PC Pump
Slurry pump: 100–400 RPM
Selected
CT-100D Peristaltic Pump
Slurry pump: 6–26 RPM
Selected
Base slurry density Default: 110 PCF  
Cellular densityRange: 25 – 75 PCF
Foam densityRange: 2.0 – 4.0 PCF, step 0.25
Slurry pump speedRange: 100 – 300 RPM
Truck loadRange: 1 – 10 yd³
CFM slurry output
—
CFM
⬟ Foam setting (recommended)
—
CFM
Total output
—
CY / hr
Time to empty truck
—
minutes
⚠ Important Note
Machine settings and production rates are calculated values — actual values may vary. Always take a sample to verify your density and adjust accordingly.

• Density too high? Increase foam setting or decrease slurry pump speed.
• Density too low? Decrease foam setting or increase slurry pump speed.
Units
CFVT-20C
Fixed foam output: 20 CFM  ·  Foam density: 2.3 PCF  ·  Water:concentrate: 45:1
Base slurry densityDefault: 110 PCF
Cellular densityDefault: 30 PCF
Cellular slurry volume per truckDefault: 7 yd³
Wet cellular density
—
lbs / ft³
Base slurry volume
—
yd³
Volume of foam needed
—
ft³
Machine run time
—
minutes
Water required
—
gal
CMX concentrate required
—
gal
Purchase CMX Foam Concentrate
⚠ Important Note
All values are calculated based on fixed machine constants (foam output: 20 CFM, foam density: 2.3 PCF, water:concentrate ratio: 45:1). Actual values may vary. Always verify with a sample before production.
Units
Host pipe diameterinches
Liner pipe diameterinches
Lengthfeet
Segment volume
—
yd³
Units
CT-30D
Slurry pump: 100–300 RPM
Selected
CT-100D PC Pump
Slurry pump: 100–400 RPM
Selected
CT-100D Peristaltic Pump
Slurry pump: 6–26 RPM
Selected
1
Prepare equipment
This test requires a drum of known volume. If a scale is available, place the drum on the scale — this will help determine foam density.
2
Enter drum volume
Drum volumeDefault: 55 gal
3
Set foam output
Set foam to — CFM on the machine display.
Set value on displayCFM
4
Fill the drum
Once the machine is making good foam, fill the drum completely and time it.
5
Enter results
Time to fill drumseconds
Weight of foamlbs (optional)
6
Results
Calculated foam flow
—
CFM
Foam density
—
lbs/ft³
ℹ Foam density requires a scale — enter foam weight above to calculate it. Typical range is 2.0–4.0 lbs/ft³. If calculated, use this value to update foam density in Tab 1 (Mix Design) and Tab 2 (CT Settings) for more accurate results.
Units
Richway Industries
Mix Design App
©
Copyright
© 2025 Richway Industries. All rights reserved.
Unauthorized reproduction or distribution of this application or its contents is strictly prohibited.
🌐
Website
www.richway.com
›
📞
Phone
319-987-2976
›
✉️
Email
info@richway.com
›
📍
Address
504 N Maple St
Janesville, IA 50647
›
Version 1.0.0  ·  Built for CT Series Machines